{"product_id":"g-med-auren-a10-infusion-pump","title":"G-MED AUREN A10 Infusion Pump","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eG-MED AUREN A10 Infusion Pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for controlled delivery of infusion fluids at a set rate. It is intended for use by trained healthcare professionals who require adjustable infusion settings and monitoring of the infusion process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eContact GMED to enquire about the AUREN A10 configuration, technical specifications, availability and quotation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Infusion Settings\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe referenced infusion-pump platform supports setting the infusion rate and infusion volume according to the selected operating mode and clinical requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Infusion Modes\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe technical reference documents two operating modes: ml\/h and drop\/min. Confirm the modes available on the supplied AUREN A10 configuration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfusion Monitoring and Alarms\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe reference manual describes alarms for conditions such as occlusion, air bubbles, an open door, low battery and completion of infusion. Exact alarm functions should be confirmed for the AUREN A10 configuration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-Bubble Detection\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe reference platform uses ultrasonic detection to identify air bubbles in the infusion set.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOcclusion Pressure Settings\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe reference manual documents high, medium and low occlusion-pressure settings.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Backup\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe reference manual specifies an internal rechargeable battery for operation when mains power is unavailable. Actual runtime depends on the confirmed configuration and operating conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cstrong\u003eReference-manual details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eG-MED AUREN A10 Infusion Pump\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eVolumetric Infusion Pump\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eInfusion modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eml\/h and drop\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eRate range, ml\/h mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e1–1,200 ml\/h, in 1 ml\/h increments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eRate range, drop\/min mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e1–266 drops\/min, in 1 drop\/min increments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eRate accuracy, ml\/h mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e≤ ±5% after calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 39.1875px;\"\u003e\u003cstrong\u003eRate accuracy, drop\/min mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 39.1875px;\"\u003e\u003cspan\u003e≤ ±3% after calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eInfusion volume setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e1–9,999 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eTotal infusion volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e0–9,999.9 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eKVO rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e1–5 ml\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eOcclusion pressure levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eHigh, medium and low\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eAir-bubble detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eUltrasonic; sensitivity ≥25 μL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e100–240 V AC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eInternal rechargeable lithium battery, 11.1 V, capacity ≥1,800 mAh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery runtime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003eMore than 4 hours at 25 ml\/h under the reference manual's stated conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e40 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e153 × 162 × 227 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.8034%; height: 19.5938px;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.8609%; height: 19.5938px;\"\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIntended Use\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe reference manual describes use for controlled administration of drug fluids through clinically accepted IV routes under the supervision of trained healthcare professionals. The manual states that the referenced device is not intended for blood transfusion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConfirm the approved intended use and claims for the marketed AUREN A10 product before publication.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFAQ\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the G-MED AUREN A10 Infusion Pump?\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eIt is GMED's named infusion-pump product. Contact GMED for details of the supplied configuration and technical specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhich infusion modes are documented in the reference manual?\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eThe reference manual documents ml\/h and drop\/min modes. Confirm availability on the AUREN A10 configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDoes the reference platform have alarms?\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eYes. The manual describes alarms for conditions including occlusion, air bubbles, an open door, low battery and infusion completion. The exact AUREN A10 alarm configuration should be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDoes the reference platform include battery backup?\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eThe manual specifies an internal rechargeable battery. Confirm the battery specification and runtime for the supplied AUREN A10 unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHow can I request a quotation?\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eSelect \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGET QUOTE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to contact GMED for product information, configuration details and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInterested in the G-MED AUREN A10 Infusion Pump? Contact GMED to discuss your requirements and request a quotation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Genique Medcrop Pvt. Ltd.","offers":[{"title":"Default Title","offer_id":67864100208829,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/6105\/4653\/files\/G-MEDSYRINS10front_a82b76d9-004a-43e9-912d-54303d5f39ab.webp?v=1792741448","url":"https:\/\/www.gmedcrop.com\/products\/g-med-auren-a10-infusion-pump","provider":"Genique Medcrop Pvt. Ltd.","version":"1.0","type":"link"}